元器件交易网www.cecb2b.com
Multi-Output HP600 AC-DC Front End Data Sheet
Features
• Compact 1U design
• N+1 redundancy with hot plug capability • Up to five individually-regulated outputs • 6.52 Watts/in3 power density
• I2C interface with interrupt capability
• Hot-swap with low insertion/extraction force connector • Power factor corrected • No minimum load required • 5 V @ 1 A standby output • Single-wire current sharing • Self-contained ORing diodes
• Overcurrent and overvoltage protection • Full power up to 50 ºC • TUV, cTUVus & CB report • 600 watts per module • Two-year warranty
Description
The HP600 provides up to 600 watts of output power with one to five main outputs ranging from 0.8 to 48 Volts,
plus a 5V standby output. These hot-swap products incorporate internal ORing diodes and support paralleling and current sharing for up to three main outputs, excluding the -12V output. This multiple-output, hot-swap capability accelerates time-to-market in networking applications requiring several high-current rail voltages and/or instances where sufficient board space is not available to implement distributed power and intermediate bus architectures.
Model Selection
HP6 Front End Models
HP600-X8X4X4D2D-O HP600-X8X4X4D4D-O HP600-X4X4X4D4D-O HP600-X4X4X4D2D-O
Output Voltage X = A (2.0V); B (3.3V); C (5V); *F (24V @ 120W); *J (48V @ 120W); T (2.5V); V (1.8V); W (1.5V); X (1.2V); Y (1V); Z (0.8V)
Options O = B (I2C); M (Output power good – TTL high); N (Power fail – TTL high); R (Reverse airflow)
Please contact Power-One for additional model combinations.
V1 V2 V3* V4 V5 Volts Amps Volts Amps Volts Amps Volts Amps Volts Amps X 80 X 40 X 40 12 20 -12 3 X 80 X 40 X 40 12 40 -12 3 X 40 X 40 X 40 12 40 -12 3 X 40 X 40 X 40 12 20 -12 3
May 16, 2007 revised to JUN 8, 2007 Page 1 of 6 www.power-one.com
元器件交易网www.cecb2b.com
Multi-Output HP600 AC-DC Front End Data Sheet
Input Specifications
AC Input Voltage Input Frequency Hold-up Time Inrush Surge Current Power Factor
Single-phase continuous input range. AC input.
85 47
2 63 40 0.99
VAC Hz ms A pk W/VA
Parameter Conditions/Description Min. Nom. Max. Units After last AC line peak at full power.
At 115 VAC. 20 Hot and cold start.
At full load and nominal line.
Output Specifications
Output Voltage and Current Ratings Efficiency Minimum Load Output Power
See Model Selection table. Typical at full load, nominal input. No minimum load required.
78 0
Parameter Conditions/Description Min. Nom. Max. Units % A W
%
600 < 1 < 3
Overshoot/Undershoot Output voltage overshoot/undershoot at turn-on
or turn-off.
50% to 100% load step. Start-Up Time
Time required for initial output voltage
stabilization after application of AC input or ON/OFF signal.
Single-Wire Share (V1, V2, V3, and +12V) 10% full-load rating
Compensates for voltage drop of up to 0.5V to the load (V1, V2, V3, and +12V). Shorted sense lead protection.
Load with remote sense: Load without remote sense:
Line over entire operating range: Cross:
PARD: 1% or 50 mV pk-pk, whichever is greater; measured at 20 MHz bandwidth.
< 2 S Current Share Remote Sense
Regulation
0.5
2 % 0.1 <5
Output Noise and Ripple
May 16, 2007 revised to JUN 8, 2007 Page 2 of 6 www.power-one.com
元器件交易网www.cecb2b.com
Multi-Output HP600 AC-DC Front End Data Sheet
Interface Signals and Internal Protection1
LED Power Good Indicator LED AC Good Indicator Enable
Output Good Signal Power Fail Signal
Front panel green LED indicates power supply is good; amber indicates a fault.
Front panel green LED indicates AC input voltage is present and above minimum level. Normally TTL High; drive Low to enable. TTL compatible signal; normally Low (goes high when power supply is out of specified range). TTL compatible signal; normally Low (indicating AC input voltage is present and above minimum level).
Internal 15A line fuse.
All outputs set at 115 to 135% of nominal. Reset by cycling input power.
All outputs set at 115 to 135% of full rated load with automatic recovery.
Parameter Conditions/Description Min. Nom. Max. Units
Input Protection Overvoltage Protection Overcurrent Protection Overtemperature Protection
Automatic shutdown with automatic recovery.
Safety, Regulatory, and EMI Specifications
Agency Approvals Electromagnetic Interference Voltage Fluctuation and Flicker ESD Susceptibility Radiated Susceptibility EFT/Burst Input Transient Protection RF Conducted Immunity Leakage Current Dielectric Withstand
TUV, cTUVus, & CB Report Meets EN55022, Class B.
Parameter Conditions/Description Min. Nom. Max. Units Harmonics Meets IEC61000-3-2.
Per IEC61000-3-3, Criteria B. Per EN61000-4-2, Criteria B. Per EN 61000-4-3, Criteria A. Per EN 61000-4-4, Criteria B. Per EN 61000-4-5, Criteria B. Per EN 61000-4-6, Criteria A. At 240 VAC, 50 Hz Input-to-Ground:
Input-to-Output: Output-to-Case:
. . . . . 1.2
mA
2200
4300 VDC 25
May 16, 2007 revised to JUN 8, 2007 Page 3 of 6 www.power-one.com
元器件交易网www.cecb2b.com
Multi-Output HP600 AC-DC Front End Data Sheet
Environmental Specifications
Altitude Operating. Non-Operating. Operating Temperature Storage Temperature Temperature Coefficient Relative Humidity
Internal DC fan for cooling.
0 ºC to 50 ºC Non-condensing.
10K ASL ft
40KASL ft 0 -40
50
Parameter Conditions/Description Min. Nom. Max. Units ºC ºC %/ºC %RH
85 0.02 95
Reliability
MTBF
(Calculated) @ 25 °C, Bellcore Standard.
250 000
Parameter Conditions/Description Min. Nom. Max. Units hrs
I2C Interface
The HP600 I2C interface provides highly-integrated error monitoring and analyses, and includes the following
features:
Event-Driven Messages:
• Notification of fan-speed abnormality • Output voltage under specified 'good' range • Output voltage over specified 'good' range (software OVP) • Temperature abnormalities
Sensor Device Commands:
• • • Get voltage readings
Get temperature readings Get fan-speed readings
FRU (Field Replaceable Unit) Information Storage:
• Manufacturer's name • Product name • Product part/model number • Product version/revision • Product serial number
May 16, 2007 revised to JUN 8, 2007 Page 4 of 6 www.power-one.com
元器件交易网www.cecb2b.com
Multi-Output HP600 AC-DC Front End Data Sheet
Mechanical Specifications
Size: 1.6\" H x 5\" W x 11.5\" D (40.6 x 127 x 292.1 mm) Connector: FCI 51939-046
I/O Mating Connector: FCI 51921-001
May 16, 2007 revised to JUN 8, 2007 Page 5 of 6 www.power-one.com
元器件交易网www.cecb2b.com
Multi-Output HP600 AC-DC Front End Data Sheet
Output Connector Details
J1 DC Output and Signal Interface Pinout
Pin No. 1 2
Signal Name V4 Output (+12V) V4 Output (+12V)
Pin No. A1 A2
Signal Name +Sense V1 Share V3
3 Ground A3 Share V1 4 Ground A4 Share V4 5 7
V1 Output V1 Output
A5 B2
DC Enable +Sense V3
6 V1 Output B1 Present 8 Ground B3 Share V2 9 Ground B4 +Sense V2 10 V2 Output B5 11
V2 Output
C1
SCL V5 Output (-12V)
12 Ground C2 5V Standby 13 Ground C3 +Sense V4 14 16 17 18
V3 Output Chassis AC Low AC High
C4 D1 D2 D3 D4
- Sense A1 V5 Output (-12V) 5V Standby Power Fail * Power Good **
15 V3 Output C5 D5 SDA
NOTES:
* AO with IC option ** Interrupt with IC option
2
2
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice.
May 16, 2007 revised to JUN 8, 2007 Page 6 of 6 www.power-one.com